ORE 3% Screen Shade Solar Control Vertical Blinds Flame Retardant
ORE 3% Screen Shade Solar Control Vertical Blinds Flame Retardant
3 Weeks or Less
UK Mainland Over £250
FREE
ORE 3% Screen Shade Solar Control Vertical Blinds Flame Retardant: Made-to-Measure Glare Control (BS5867 Type B)
A made-to-measure vertical blind using the ORE solar control screen fabric, specified where strong glare reduction is required while maintaining the comfort of natural light. Designed for contract environments including commercial, education and healthcare settings.
Flame Retardant
BS5867 Part 2, Type B
Screen Shade
Solar control focus
Free Swatch
Colour checking before order
Operation
Chain control
Colours
7 colour options
Easy Care
Wipe clean
Expectation setting: This is a screen shade vertical blind specified for solar control and glare reduction. It is not blackout. Light and shading performance will vary by colour selection and site conditions.
Why specify ORE solar control vertical blinds
ORE is a contract-suited vertical blind option designed for areas needing a high level of solar control while maintaining natural light. It is used to help reduce glare in practical working environments.
Supplied as a made-to-measure vertical blind with louvre width options to suit different window sizes and visual preferences. The screen construction is also stated as suitable for computer environments.
Fire performance is stated as BS5867 Part 2, Type B. For project documentation and any supporting certificates, refer to the Specifications tab.
Where this fits in our range
Choose ORE when the priority is solar control with a screen shade finish and a contract-appropriate flame retardant rating. If full light exclusion is required, specify a blackout blind solution instead.
Best suited for
- Education: classrooms and IT suites needing glare management while keeping rooms bright.
- Healthcare: circulation areas and support rooms requiring controlled daylight and wipe-clean maintenance.
- Commercial: offices and workspaces where screen suitability supports computer use.
Who uses ORE flame retardant vertical blinds
Specified for public-facing and operational spaces where glare control supports comfort and usability, including commercial premises, education environments and healthcare settings.
Suitable where wipe-clean maintenance is required, and where screen performance is needed for computer environments.
Made-to-measure, contract-led ordering
Order by finished width and drop to suit your window. Use the room/reference field to support site identification on delivery. Free swatches are available to confirm colour selection before manufacture.
Technical specifications
| Product type | Vertical blinds (made to measure) |
| Operation | Chain |
| Fabric composition | 70% PVC, 30% Polyester |
| Colour range | 7 colours |
| Louvre widths | 127mm (5”), 89mm (3.5”), 63mm (2.5”) |
| Fabric width | 2500mm (98½”) |
| Fabric thickness | 0.50mm |
| Fabric weight | 400 g/m² |
| Fire retardancy | BS5867 Part 2, Type B (Certified rating shown as BS5867 Part 2B) |
| Acoustic absorption | E Rating |
| Shading | High performance |
| Screen suitability | Suitable for computer environments |
| Moisture resistance | Suitable for moist conditions |
| Care instructions | Wipe clean |
| Mesh/in | 48 x 48 |
| Colour fastness | 4.5 |
| Typical lead time shown | 3 weeks or less |
For specification-critical work, confirm project requirements and request certification via the Specifications tab. Care instructions and supporting documentation should be retained for handover packs.
Screen fabric information
Reference image provided for the ORE screen fabric solar control information.
Installer note: Confirm finished width, finished drop and louvre width selection before manufacture. For contract sign-off, retain care guidance and certification documents from the specification tab.
| Flame Retardant Certified Rating | BS5867 Part 2B |
|---|---|
| Acoustic Absorption Rating | E Rating |
| Fabric Style | Plains |
| Features | Flame Retardant, Screen Fabric, Voile |
| Operation | Chain |
| Delivery | 3 Weeks or Less |
| Flame Retardant | Yes |
Are my products certified for use in a public place?
What types of blinds do you offer?
Are all your blinds flame retardant?
Do you install blinds or is it DIY only?
What are vertical blinds best suited for?
Can I return made-to-measure curtains?
What does FR or flame retardant mean?
Do I get a certificate to show my products are flame retardant?
Customer Product Reviews
Top customer reviews
-
Excellent after-sales supportI have ordered vertical blinds from Direct Fabrics but they weren't exactly the ones I wanted. The sales team sorted the problem really quickly and with clear communication. Really outstanding customer service!0 people found this helpful
-
excellent service & productSince I first contacted them until the items were delivered, I received a very attentive service from the Sales Team. Samples were sent on time and delivery of blinds arrived even earlier than expected. Definetely would recommend the Vertical blinds product and the service.0 people found this helpful
How to Measure For Curtains, Blinds and Tracks.
Make sure your curtain tracks and poles are fitted in the position you want.
Choose the type of curtains that you would like and how you want to hang your curtains. See our heading styles guide
We recommend fitting your hardware first before measuring, this avoids any issues with not getting the perfect fit.
Measure your window using our main guide. Quick summary below. Remember wave, pinch, and designer headings require slightly different measurement
Measure in 3 places and take the shortest drop – Floors and ceilings can run out.
Double / Triple check your measurements

Choosing your Curtain Track Width
The width of the curtain track should extend past your window this allows for the curtains to stack back away from your window and allow light in.
Measure your recess and then add on 15cm on either side. For acoustics , we recommend further to fully cover the window and the surrounding area. In our test we added an additional 30cm to the width and also made the curtain floor length.
Wave curtains, for every 100cm of track the curtains will stack circa *18cm
Eyelet curtains, they will stack back circa 10cm per *70cm of track width
Pencil Pleat will stack approx 25% of the track width. eg. 210cm track will stack 52.5%
* all dependent on thickness of fabric
Selecting your Curtain Drop
Where to Measure From for Different Type of Curtains
|
Type of Curtains |
Fitted On |
Where to Measure from - to desired length |
|
Pencil Pleat Curtains |
Curtain Track |
Top of the Track - If using a extra wide track or designer track like silent gliss metropole, then measure from the underside of the track. |
|
Pencil Pleat Curtains |
Curtain Pole |
Measure from small ring at the bottom of eye under the ring, this is where your curtain clips into. |
|
Eyelet Curtains |
Curtain Pole – Only |
Top of the pole *we add on the upstand to our curtains, |
|
Pinch Pleat Curtains |
Curtain Track |
The underside of the track |
|
Wave Curtains |
Curtain Track Designer Pole |
The glider underneath the track. The curtain will sit under the track. |
|
Acoustic Curtains |
See Heading Style of Choice above |
Same but make sure wider than normal ideally 30cm past either side and 30 above. Also to the floor. |
How to Measure for Blinds going Inside the Recess
- Measure the exact width of the recess in three places; at the top of the recess, in the centre of the recess and near the bottom - then take the smallest size.
- Measure the exact drop of the recess in three places on the left hand side of the recess, in the centre of the recess and on the right hand side of the recess - then take the smallest size.
- We will take one cm off the finished width size you have given us, to allow for the blind to pull up and down easily.
- Double check your measurements
- Cord Safety - Mounting Height - We ask for the mounting height of your blinds to allow for the cord to be 150cm off the ground. If mounting at 210cm This is what you enter in the Fitting height box. We make a deduction to ensure the cord is 150cm from the floor. Thus the cord loop will be 60cm
How to Measure Outside of the Recess
- Measure the recess in 3 places on the width and also 3 places on the drop. Take the widest measurement.
- Measure the width of the actual recess plus an additional amount – Usually from 7cm-15cm whatever you think looks appropriate. This is for overlap.
- Measure the exact drop of the recess. The blind would be fitted above the recess, so check the space above and add an amount on to the drop – usually from 7-15cm
- These sizes you have taken will be the size of the finished blind.
- Double check your measurements
- Cord Safety - Mounting Height - We ask for the mounting height of your blinds to allow for the cord to be 150cm off the ground. If mounting at 210cm This is what you enter in the fitting height box. We make a deduction to ensure the cord is 150cm from the floor. Thus the cord loop will be 60cm
Cubicle Tracks you have to measure with right angles from wall to wall where you want the track to go
Draw your room on a piece of paper with a sky view
Now measure from the wall to wall for straight tracks,
L Shape Tracks Measure to a point on the floor and mark with a piece of tape. Then for the other sides measure from the other wall to that point.
Always check for obstructions and fitting issues you may need to work around
SAVE TIME - Send your project requirements, large or small. Sample Lists etc